Memos for the June 2007 ICC-ES Evaluation Committee Meeting:
Tuesday, June 5, 2007
- AC133-Steel
Bar Reinforcement Reinforcing Bars.
Revisions are proposed to update the criteria, clarify some of its sections,
and address issues arising from cases of multiple manufacturing locations.
click
here
- AC04-Sandwich Panels. Revisions are aimed at providing a uniform
approach to evaluation of products used as shear walls resisting seismic
forces. Other proposed revisions include updating the criteria and editorially
clarifying some of its provisions. click
here
- AC358-Helical Foundation Systems and Devices. A new criteria is
proposed for determining structural capacities of helical foundation systems.
An earlier version of this criteria was discussed at the February 2007 Evaluation
Committee hearing. click
here
- AC17-Glass Glazed Unit Skylights and Sloped Glass Glazing. Following
a period of public comment, revisions are proposed to update the criteria
to the 2006 International Codes, to add provisions for PVC glazing retainers
and frames, and to include specifications for weather-sealing materials.
click
here
- AC16-Plastic Glazed Skylights. Following a period of public comment,
revisions are proposed to revise conditions of acceptance for some testing,
to include specifications for water-sealing materials, to limit use of skylights
with plastic frames, and to update the criteria to the 2006 International
Codes. click
here
- AC86-Cold-formed Steel Framing Members-Interior Nonload-bearing Wall
Assemblies. Extensive revisions are proposed, based upon discussions
at a meeting involving an industry task group and ICC-ES staff. click
here
Wednesday, June 6, 2007
- AC193-Mechanical Anchors in Concrete Elements. Numerous issues
have been raised by ICC-ES staff and industry that may require revisions
to the criteria. click
here
- AC308-Post-installed Adhesive Anchors in Concrete Elements. Numerous
issues have been raised by ICC-ES staff and industry. Several revisions
are proposed to the criteria's Annex A. click
here
- AC15-Concrete Floor, Roof and Wall Systems and Concrete Masonry Wall
Systems. Revisions are proposed to limit the application of this criteria
for wall systems to certain seismic design categories and seismic zones.
The criteria is also updated and editorially revised. click
here
- AC375-Field-constructed Fireplace Systems Using Prefabricated Blocks.
A proposed new acceptance criteria applies to fireplace systems (fireplace
unit and chimney) that are assembled in the field using prefabricated blocks
of either refractory masonry or reinforced precast lightweight concrete
masonry. click
here
- AC275-Glass Fiber Lath Used in Cementitious Exterior Wall Coatings,
Exterior Cement Plaster (Stucco) or Precast Stone Veneers. Revisions
are proposed to update the criteria to the 2006 International Codes and,
in line with a request from a report applicant, to add use of glass fiber
lath in exterior stucco supporting precast stone veneer. click
here
Thursday, February 8, 2007
- AC378-Fiber-cement Interior Substrate Sheets Used in Wet and Dry Areas.
A new criteria is proposed for reinforced cementitious substrate sheets
complying with ASTM C 1288, and used as interior sheathing boards and membranes.
click
here
- AC376-Reinforced Cementitious Sheets Used as Sheathing. A new
criteria is proposed for reinforced cementitious sheets complying with ASTM
C 1325, and used as exterior sheathing boards and interior membranes. click
here
- AC367-Reinforced Cementitious Flat Sheets Used as Subfloor or Single
Floor Panels. After a period of public comment, a new criteria is proposed
for flat sheets as described, used as panels for subfloors or single floors.
Input is needed from industry. click
here
- AC269-Racking Shear Evaluation of Proprietary Sheathing Materials
Used as Braced Wall Panels. Revisions are proposed to clarify anchor
bolt size and spacing requirements, and to remove from the criteria certain
seismic design categories. click
here
- MISC1-Staff Work on AC322. Information will be supplied to interested
parties regarding efforts by ICC-ES staff to develop a criteria for cold-formed
steel lateral-force-resisting (LFR) elements. Other criteria (AC04, AC130,
AC154, AC269) may be affected. click
here
- AC11-Cementitious Exterior Wall Coatings. The criteria is on the
agenda so staff may to seek input regarding drainage requirements when cementitious
exterior wall coatings are installed on solid-sheathed, framed assemblies
using foam plastic insulation board. click
here