Resolution of items presented at the February 2010 ICC-ES Evaluation Committee Meeting:
- AC424 — Proposed Acceptance Criteria for Wood-Based Exterior Composite Trim Treated with Zinc Borate (ZB) Preservative by a Non-Pressure Process. (Held for further study) Click here.
- AC365 — Proposed Revisions to the Acceptance Criteria for Building-integrated Photovoltaic (BIPV) Roof Panels. (Effective March 1, 2010) Click here.
- AC66 — Proposed Revisions to the Acceptance Criteria for Fire-retardant-treated Wood. (Effective March 1, 2010) Click here.
- AC423 — Proposed Acceptance Criteria for a Low Profile, Raised Deck System Installed Over a Roof Assembly or Exterior Structural Floor Substrate. (Held for further study) Click here.
- AC203 — Proposed Revisions to the Acceptance Criteria for Zinc Borate (ZB) Preservative Treatment of Structural Composite Lumber by Non-Pressure Processes. (Effective March 1, 2010) Click here.
- AC421 — Proposed Acceptance Criteria for Vertically-acting Egress Fire-door Assemblies. (Held for further study) Click here.
- AC39 — Proposed Revisions to the Acceptance Criteria for Walking Decks. (Effective March 1, 2010) Click here.
- AC417 — Proposed Acceptance Criteria for 1/2-inch Sag-resistant Gypsum Ceiling Board Installed with Two-part Polyurethane Adhesive. (Effective March 1, 2010) Click here.
- AC391 — Proposed Revisions to the Acceptance Criteria for Continuous Rod Tie-Down Assemblies. (Effective March 1, 2010) Click here.
- AC193 — Proposed Revisions to the Acceptance Criteria for Mechanical Anchors in Concrete Elements. (Effective March 1, 2010) Click here.
- AC422 — Proposed Acceptance Criteria for Continuous and Semi-continuous Fiber-Reinforced Grid Connectors Anchored in Concrete. (Held for further study) Click here.
- AC43 — Proposed Revisions to the Acceptance Criteria for Steel Deck Roof and Floor Systems. (Held for further study) Click here.
- AC118 — Proposed Revisions to the Acceptance Criteria for Tapping Screw Fasteners. (Held for further study) Click here.
- AC70 — Proposed Revisions to the Acceptance Criteria for Fasteners Power-driven into Concrete, Steel and Masonry Elements. (Effective March 1, 2010) Click here.
- AC259 — Proposed Revisions to Acceptance Criteria on Pneumatic- or Gas-Power-Driven Pin Fasteners Used to Attach Gypsum Panels to Cold-Formed Steel Framing. (Held for further study) Click here.
- AC46 — Proposed Revisions to the Acceptance Criteria for Cold-formed Steel Framing Members. (Effective July 1, 2010) Click here.
- AC425 — Proposed Acceptance Criteria for Cold-Formed Steel Structural Beams Acting Compositely with Cast-In-Place Concrete Slabs. (Effective March 1, 2010) Click here.
- AC86 —Proposed Revisions to the Acceptance Criteria for Cold-formed Steel Framing Members-interior Nonload-bearing Wall Assemblies. (Effective March 1, 2010) Click here.
- AC347 — Proposed Revisions to the Acceptance Criteria for Headed Ends of Concrete Reinforcement. (Effective July 1, 2010) Click here.
- AC15 — Proposed Revisions to the Acceptance Criteria for Concrete Floor, Roof, and Wall Systems and Concrete Masonry Walls. (Effective March 1, 2010) Click here.
- AC125 — Proposed Revisions to the Acceptance Criteria for Concrete and Reinforced and Unreinforced Masonry Strengthening Using Externally Bonded Fiber-Reinforced Polymer (FRP) Composite Systems. (Effective March 1, 2010) Click here.
- AC396 — Proposed Acceptance Criteria for Cellular-Wood-Fiber-Reinforced Masonry Units. (Held for further study) Click here.