  1. AC232 — Proposed Acceptance Criteria for Anchor Channels in Concrete Elements. A new criteria is proposed for anchor channels in concrete which will address application, design and installation by considering the performance of the anchorage, the steel channel, and the steel boat or screw. This subject was previously considered by the Evaluation Committee in October 2003. This version has been completely revised. Click here.
  1. AC377   Proposed Revisions to the Acceptance Criteria for Spray-applied Foam Plastic Insulation. Revisions are proposed to address the 2009 International Codes, to revise Section 3.3.3.1 to include a provision on the location of the gas burner, and to add a new Section 3.3.3.2.4 concerning the location of the wood crib. Click here.

Wednesday, June 16, 2010

  1. MISC 1 — Proposed Policy Concerning the Acceptance of Newer Editions of Design Specifications. This item has been placed on the Evaluation Committee agenda to seek input from the Evaluation Committee on whether an evaluation reports can be issued based on editions of design standards (design specifications) newer than those reverenced in the International Codes. Click here.
  1. AC391  Proposed Revisions to the Acceptance Criteria for Continuous Rod Tie-down Assemblies Used to Resist Wind Uplift. Revisions are proposed to incorporate provisions that would extend the criteria to allow evaluations to be performed on continuous rod tie-down systems which would include both the continuous rod tie-down assembly and the wood framing through which wind loads are transferred to the rods. Click here.
  1. AC316 —  Proposed Revisions to the Acceptance Criteria for Shrinkage Compensating Devices. Revisions are proposed to simplify testing of the tension-controlled shrinkage compensating devices and staff seeks input on establishing a load and resistance factor design capacity for the devices and how to address slippage situations that have been observed in testing these devices. Click here.

Thursday, June 17, 2010

  1. AC166  Proposed Revisions to the Acceptance Criteria for Metal Roof Coverings. Revisions are proposed to the criteria that would set forth requirements for metal roof coverings used as a substitute for roof deck sheathing for the purpose of resisting lateral loads under the International Residential Code. Click here.

  2. AC47 —  Proposed Revisions to the Acceptance Criteria for Structural Wood-based Products. Revisions are proposed to include provisions for thermally modified wood in the criteria. Click here.

  3. AC424 — Proposed Acceptance Criteria for Wood-based Exterior Composite Trim Treated with Zinc Borate (ZB) Preservative by a Non-Pressure Process. A new criteria is proposed for exterior wood-based exterior composite trim treated with ZB preservative by a non-pressure process. This subject was previously considered by the Evaluation Committee in February 2010. Click here.

  4. AC405 —  Proposed Revisions to the Acceptance Criteria on Wood Structural Panels with Factory-applied Fire-retardant Coatings. A new acceptance criteria is proposed for wood structural panels with factory-applied fire-retardant coatings used to provide fire wall continuity. This item has previously been considered by the Evaluation Committee several times, June 2009 being the last time. Click here.