Tuesday, February 14, 2012
1:00 PM Start

  1. AC264 — Proposed Revisions to the Acceptance Criteria for Wood Structural Panels Laminated with an Inert, Inorganic Fire Shield. Revisions are proposed to update the criteria to include the 2012 codes, add a definition for “inert, inorganic fire shield”, add provisions to allow recognition of the product for use in exterior walls of buildings of Type III-A construction, and incorporate editorial revisions. Click here.
  1. AC188 — Proposed Revisions to the Acceptance Criteria for Roof Underlayments. Revisions are proposed to update the criteria to include the 2009 and 2012 codes and delete the UBC; clarify that the criteria provides an alternate means to qualify self-adhered membranes as roofing underlayments; clarify that the products may be optionally qualified for additional uses such as with fire classified roofing, as an ice barrier when two layers are cemented together, and with adhesively attached roofing tiles as well as setting forth requirements to address how these applications can be qualified; update referenced standards; update quality control requirements to reflect changes made to AC304; add a requirement that a condition of use be included in evaluation reports to clarify how fire classification requirements of the codes were addressed; and seek input as to whether future revisions to the criteria should delete the condition of use limiting the underlayments to roofs having vented attic spaces. Click here.

Wednesday, February 15, 2012
8:00 AM Start

  1. AC308 — Proposed Revisions to the Acceptance Criteria for Post-Installed Adhesive Anchors. Revisions are proposed to clarify that the provisions for the assessment of multiple anchors in Annex A, Section 4.5.1 apply to threaded rods, not reinforcing bars; clarify that test specimens used for the punch tests included in the durability assessment provisions of Annex A, Section 9.8 must be tested within a certain time period from being removed from storage and that moisture content within that time period must not be allowed to decline; and incorporate editorial revisions. Click here.

Thursday, February 16, 2012
8:00 AM Start

  1. AC326 — Proposed Revisions to the Acceptance Criteria for Proprietary Wood Preservative Systems – Common Requirements for Treatment Process, Test Methods and Performance. Revisions are proposed to update the criteria to include the 2012 codes; list the appendices of the criteria in Section 1.2 of the criteria; and add provisions concerning identification on nonconforming materials that are to be segregated in accordance with AC10. Additionally, the cover letter to this criteria outlines recommendations of an industry task force concerning removing certain criteria from the ICC-ES website (effectively asking ICC-ES to withdraw these criteria due to those products now being addressed in the appendices of AC326). Further, the ICC-ES staff is seeking additional input on the disclaimer proposed by AWPA that was discussed at the October 2011 meeting (a report from an industry task force may be available prior to the committee meeting). Click here.